NSN 5950-01-104-7472 · NIIN 011047472 · FSC 5950
NO DASHES 5950011047472
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 4.000 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.400 AND INCHES MAXIMUM 3.515 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.110 AND INCHES MAXIMUM 3.140 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 3.120 AND INCHES MAXIMUM 3.150 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 3.720 AND INCHES MAXIMUM 3.780 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.196 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY AMPERES AC MAXIMUM 1.6 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 4.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 2.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 3.5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 20.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 9.50 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 20.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 9 |
Supersedes
This item replaces cancelled NIIN 011496318. An older drawing citing one of those numbers resolves here.