NSN 4140-01-301-0718 · NIIN 013010718 · FSC 4140
NO DASHES 4140013010718
In Stock
FAN,TUBEAXIAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABGL | WIDTH | INCHES NOMINAL 3.140 |
| ABRY | LENGTH | INCHES NOMINAL 1.500 |
| ADNK | FLOW DIRECTION | INWARD |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS 125.0 |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 2930.0 AND 3520.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | CONNECTOR |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FLANGE 2 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE MINIMUM 28.0 AND CUBIC FEET PER MINUTE MAXIMUM 35.0 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 |
| CSYL | PRIME MOVER POWER RATING | WATTS 13.0 AND WATTS 13.3 |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 2.812 |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
| HGTH | HEIGHT | INCHES NOMINAL 3.140 |
| MATT | MATERIAL | OVERALL ALUMINUM |
| STYL | STYLE DESIGNATOR |