Home / MS parts / Electrical & Electronic Components / NSN 5950-00-906-3146
NSN 5950-00-906-3146  ·  NIIN 009063146  ·  FSC 5950
NO DASHES 5950009063146
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

18 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERSSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 0.250
AARGRELIABILITY INDICATORNOT ESTABLISHED
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 60.0 AND HERTZ MAXIMUM 400.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 5.00
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
ABKWOVERALL HEIGHTINCHES NOMINAL 2.000
AKPVMOUNTING FACILITY QUANTITY2
AXGYMOUNTING METHODSINGLE GROUP THREADED STUD(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.112
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MINIMUM 120.0 AND MILLIAMPERES AC MAXIMUM 230.0
AEHZMAXIMUM OPERATING TEMPCELSIUS 105.0
ADAQBODY LENGTHINCHES NOMINAL 1.000
TTQYTERMINAL TYPE AND QUANTITYTURRET 4
ADATBODY WIDTHINCHES NOMINAL 1.000
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 117.00
AKNAINCLOSURE TYPEHERMETICALLY SEALED

Supersedes

This item replaces cancelled NIIN 012096702. An older drawing citing one of those numbers resolves here.