NSN 6130-01-017-0988 · NIIN 010170988 · FSC 6130
NO DASHES 6130010170988
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Technical characteristics
38 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 7.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.950 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.670 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SECOND OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | FIRST OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | FIRST OPERATING POWER RQMT AC VOLTS NOMINAL 230.0 |
| APNX | INPUT VOLTAGE RATING | SECOND OPERATING POWER RQMT AC VOLTS NOMINAL 115.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 12.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL -12.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL -15.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 50.0 |
| BGHX | OUTPUT CONTROL QUANTITY | 1 |
| BGHY | OUTPUT CONTROL TYPE | FOURTH POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGHY | OUTPUT CONTROL TYPE | THIRD POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGHY | OUTPUT CONTROL TYPE | FIRST POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGHY | OUTPUT CONTROL TYPE | SECOND POWER OUTPUT VOLTAGE ADJUSTMENT |
| BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
| CBBL | FEATURES PROVIDED | FILTER |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 1.5 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 1.7 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL -1.7 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES NOMINAL -1.5 |
| CWHC | OUTPUT CONTROL LOCATION | THIRD POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FOURTH POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | SECOND POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FIRST POWER OUTPUT FRONT PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 4 |
| CWHJ | OUTPUT CONNECTION TYPE | FIRST POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | SECOND POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | THIRD POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | FOURTH POWER OUTPUT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | SECOND OPERATING POWER RQMT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | FIRST OPERATING POWER RQMT TERMINAL STRIP |
| CWHT | INPUT CONNECTION QUANTITY | 2 |