NSN 5930-01-112-5480 · NIIN 011125480 · FSC 5930
NO DASHES 5930011125480
In Stock
SWITCH,THERMOSTATIC
Switches
Application: 4310010437604 16004
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AGAV | END ITEM IDENTIFICATION | 4310010437604 16004 |
| AKBY | TEMP SENSING ELEMENT TYPE | BULB |
| AWTN | OPERATING TEMP RATING | FAHRENHEIT MINIMUM -65.0 AND FAHRENHEIT MAXIMUM 350.0 |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| CMLP | THREAD QUANTITY PER INCH | 14 |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | SINGLE THREADED BUSHING INCHES 0.500 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | THIRD VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT NOMINAL DEGREES FAHRENHEIT 215.00 AND DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT 195.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE AC AT SEA LEVEL 120.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | THIRD VOLTAGE DC AT SEA LEVEL 30.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 240.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| THSD | THREAD SERIES DESIGNATOR | SINGLE THREADED BUSHING NPTF |