Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| ABJH | TEMP RATING | CELSIUS -55.0 AND CELSIUS 200.0 |
| ADVL | CROSS SECTION OUTSIDE DIAMETER | INCHES MINIMUM 0.104 AND INCHES MAXIMUM 0.128 |
| AGAV | END ITEM IDENTIFICATION | AN/TTC-39E(V)1 |
| AKRZ | TERMINATION TYPE | SECOND END ALL CONDUCTORS CONNECTOR PLUG |
| AKRZ | TERMINATION TYPE | FIRST END ALL CONDUCTORS CONNECTOR RECEPTACLE |
| ALBY | USAGE DESIGN | SWITCHBOARD WIRE |
| AMQN | CONDUCTOR QUANTITY | 2 |
| AWTB | ACCESSORY WIRE TYPE AND QUANTITY | GROUND 1 |
| CXCW | CONDUCTOR FORM | SECOND CONDUCTOR BRAID, TUBULAR |
| CXCW | CONDUCTOR FORM | THIRD CONDUCTOR BRAID, TUBULAR |
| CXCW | CONDUCTOR FORM | FIRST CONDUCTOR STRANDED |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY ELECTRICAL-SIGNAL |
| CXDC | ROUND CONDUCTOR SIZE | FIRST CONDUCTOR AWG 20.00 |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 36 |
| CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | TRIAXIAL 1 |
| CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | J72S-9 |
| CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | PL-75-2 |
| CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 14949 |
| CXGW | INDIVIDUAL CONDUCTOR LENGTH | BOTH ENDS ALL CONDUCTORS INCHES MINIMUM 52.000 AND INCHES MAXIMUM 54.000 |
| MATT | MATERIAL | FIRST POSITION SECONDARY INSULATION CABLE PLASTIC, POLYETHYLENE (PP) |
| MATT | MATERIAL | CORE CONDUCTOR FIRST CONDUCTOR COPPER |
| MATT | MATERIAL | FOURTH POSITION SHIELD BRAID METALLIC THIRD CONDUCTOR COPPER |
| MATT | MATERIAL | THIRD POSITION SECONDARY INSULATION CABLE PLASTIC FLUORINATED ETHYLENE PROPYLENE |
| MATT | MATERIAL | SECOND POSITION SHIELD BRAID METALLIC SECOND CONDUCTOR COPPER |
| MATT | MATERIAL | FIFTH POSITION COVER CABLE PLASTIC POLYVINYL CHLORIDE (PVC) |
| STYL | STYLE DESIGNATOR |