| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 7.020 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 4.020 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 4.770 |
| AGAV | END ITEM IDENTIFICATION | DATA ACQ UNIT |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 115.0 AND AC VOLTS MAXIMUM 230.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL -15.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| BGHY | OUTPUT CONTROL TYPE | SECOND POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGHY | OUTPUT CONTROL TYPE | THIRD POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGHY | OUTPUT CONTROL TYPE | FIRST POWER OUTPUT VOLTAGE ADJUSTMENT |
| BGQR | OUTPUT WATTAGE RATING | THIRD POWER OUTPUT WATTS MAXIMUM 75.0 |
| BGQR | OUTPUT WATTAGE RATING | FIRST POWER OUTPUT WATTS MAXIMUM 75.0 |
| BGQR | OUTPUT WATTAGE RATING | SECOND POWER OUTPUT WATTS MAXIMUM 75.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 2.5 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 2.5 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 20.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SECOND POWER OUTPUT MILLIVOLTS PEAK 50.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | FIRST POWER OUTPUT MILLIVOLTS PEAK 30.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | THIRD POWER OUTPUT MILLIVOLTS PEAK 30.0 |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| CWKG | VENTILATION DESIGN TYPE | AMBIENT AIR |