MRCRequirementValue
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 1.635
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 2.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 500.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 125 PCT 100.000 AND NOMINAL AT 200 PCT 0.800 AND NOMINAL AT 300 PCT 0.300 AND NOMINAL AT 400 PCT 0.170
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AKPXPOLE QUANTITY2
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
ADAQBODY LENGTHINCHES MAXIMUM 1.750
ADATBODY WIDTHINCHES MAXIMUM 0.625
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
AAQLBODY STYLE
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.687
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.303
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDWATERTIGHT
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 4
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
ABXDBUSHING LENGTHINCHES NOMINAL 0.315