NSN 5985-00-073-0719 · NIIN 000730719 · FSC 5985
NO DASHES 5985000730719
In Stock
WAVEGUIDE ASSEMBLY
Antennas, Waveguides, and Related Equipment
Application: RADAR SET AN/SPG-55
Technical characteristics
35 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQHN | WAVEGUIDE OUTSIDE WIDTH | INCHES MINIMUM 2.170 AND INCHES MAXIMUM 2.174 |
| CQJX | NOMINAL THREAD SIZE | FIRST FLANGE SINGLE CONNECTION FACILITY INCHES 0.190 |
| CQQF | OPERATING PRESSURE | POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 40.0 |
| CRFH | WAVEGUIDE INSIDE WIDTH | INCHES MINIMUM 1.870 AND INCHES MAXIMUM 1.874 |
| CRLB | WAVEGUIDE INSIDE HEIGHT | INCHES MINIMUM 0.870 AND INCHES MAXIMUM 0.874 |
| CSFC | WAVEGUIDE OUTSIDE HEIGHT | INCHES MINIMUM 1.170 AND INCHES MAXIMUM 1.174 |
| CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | INCHES MINIMUM 18.263 AND INCHES MAXIMUM 18.323 |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | FIRST FLANGE SINGLE CONNECTION FACILITY THREADED HOLE(S) 8 |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | SECOND FLANGE SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 8 |
| CTCJ | FLANGE STYLE | |
| CWBG | WAVEGUIDE OFFSET DISTANCE | INCHES NOMINAL 5.593 |
| FEAT | SPECIAL FEATURES | 3.500 IN. ALUMINUM BRACKET MTD. ON LONG LEG OF WAVEGUIDE,BRACKET HAS TWO 0.750 IN. LG. BY 0.218 IN. W. SLOTS SPACED 1.750 IN. APART ON CENTERS,TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
| FLEX | FLEXIBILITY | SINGLE TUBING SEGMENT RIGID |
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| AAJD | THREAD CLASS | 2B |
| AAJF | THREAD DIRECTION | FIRST FLANGE SINGLE CONNECTION FACILITY RIGHT-HAND |
| ACJL | BEND ANGLE IN DEG | 22.0 |
| ACJL | BEND ANGLE IN DEG | 90.0 |
| AGAV | END ITEM IDENTIFICATION | RADAR SET AN/SPG-55 |
| MATT | MATERIAL | ALL TUBING SEGMENT AND FLANGE ALUMINUM ALLOY |
| SFTT | SURFACE TREATMENT | ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES ENAMEL |
| STYL | STYLE DESIGNATOR | |
| THSD | THREAD SERIES DESIGNATOR | FIRST FLANGE SINGLE CONNECTION FACILITY UNIFIED NATIONAL COARSE (UNC) |
| ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| AHSF | FLANGE QUANTITY | 2 |
| AHSX | FLANGE INSIDE WIDTH | FIRST FLANGE INCHES MINIMUM 1.868 AND INCHES MAXIMUM 1.876 |
| AHSY | FLANGE INSIDE HEIGHT | SECOND FLANGE INCHES MINIMUM 1.002 AND INCHES MAXIMUM 2.005 |
| AHTC | FLANGE OUTSIDE DIAMETER | FIRST FLANGE INCHES NOMINAL 3.625 |
| AHTC | FLANGE OUTSIDE DIAMETER | SECOND FLANGE INCHES NOMINAL 3.625 |
| AHTD | FLANGE DEPTH | FIRST FLANGE INCHES NOMINAL 0.938 |
| AHTD | FLANGE DEPTH | SECOND FLANGE INCHES NOMINAL 0.281 |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | SECOND FLANGE SINGLE CONNECTION FACILITY INCHES MINIMUM 0.203 AND INCHES MAXIMUM 0.209 |
| AHSX | FLANGE INSIDE WIDTH | SECOND FLANGE INCHES MINIMUM 2.002 AND INCHES MAXIMUM 2.005 |
| AHSY | FLANGE INSIDE HEIGHT | FIRST FLANGE INCHES MINIMUM 0.868 AND INCHES MAXIMUM 0.876 |
| AHRV | TUBING WALL CONSTRUCTION STYLE |