NSN 6110-01-698-8916 · NIIN 016988916 · FSC 6110
NO DASHES 6110016988916
In Stock
CONTACTOR,MAGNETIC
Electrical Control Equipment
Application: POWERFLEX DRIVELOGIX PHASE II DRIVE
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| FEAT | SPECIAL FEATURES | 100S-C SAFETY CONTACTOR, 23A, LINE SIDE, 24V DC (W/ELEC. COIL), PRIM: 3N.0. 1N.C., AUX: 2N.O. 2N.C. BIFURACATED CONTACT. TAG ELEC REF: 11CR250. E-STREAM RAS SLIDING BLOCK DRIVE. DRAWING: M-P1USU00044-0011/ITEM 15, PG 1 AND 12 OF 16. |
| ABMK | OVERALL WIDTH | MILLIMETERS NOMINAL 37.34 |
| ABKW | OVERALL HEIGHT | MILLIMETERS NOMINAL 48.26 |
| ANRK | SWITCH FUNCTIONAL POSITIONS | OPEN AND CLOSE |
| ANDX | AMBIENT TEMP | CELSIUS -40.0 AND CELSIUS 60.0 |
| AFLW | ACTUATION METHOD | MAGNETIC |
| ABHP | OVERALL LENGTH | MILLIMETERS NOMINAL 44.70 |
| ACYR | DC VOLTAGE RATING | VOLTS NOMINAL 24.0 |
| ANPZ | ENCLOSURE FEATURE | ENCAPSULATED |
| AGAV | END ITEM IDENTIFICATION | POWERFLEX DRIVELOGIX PHASE II DRIVE |
| AGLD | PERFORMANCE TYPE | AUTOMATIC |
| AKPS | DUTY CYCLE | CONTINUOUS |
| AQZF | CONTROL TYPE | LOCAL |
| CBBL | FEATURES PROVIDED | ROHS DIRECTIVE COMPLIANCE |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | BRAKE AC POWER SAFETY CONTACTOR |
| ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| ANRH | AMP SIZE RATING | 23.0 |
| ACUT | DIRECT CURRENT RATING IN AMPS | 23.0 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |