NSN 5945-01-322-7008 · NIIN 013227008 · FSC 5945
NO DASHES 5945013227008
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Application: MPCD
Technical characteristics
33 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.280 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | FIRST MOUNTING FACILITY INCHES MINIMUM 0.800 AND INCHES MAXIMUM 0.820 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.810 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 0.810 |
| ABTD | MOUNTING SLOT WIDTH | FIRST MOUNTING FACILITY INCHES MINIMUM 0.123 AND INCHES MAXIMUM 0.143 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | MPCD |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS MINIMUM 90.0 AND OHMS MAXIMUM 110.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FIRST MOUNTING FACILITY SLOTTED HOLE 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SECOND MOUNTING FACILITY PLUG-IN TERMINAL(S) 1 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 0.840 |
| CQYJ | MOUNTING FACILITY PATTERN | FIRST MOUNTING FACILITY TRIANGLE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 4 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 161.0 |
| CRXH | TIME DELAY | FIXED OPERATE AND RELEASE TIME SECONDS MAXIMUM 0.006 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | FIRST MOUNTING FACILITY INCHES MINIMUM 1.062 AND INCHES MAXIMUM 1.078 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 12.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 3.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 1.0 AND AMPERES DC 1.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 3.0 AND AMPERES DC 2.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| FEAT | SPECIAL FEATURES | FAILURE RATE "M" IS 1.0 PERCENT PER 10,000 CYCLES. |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-83536 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 14 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-R-83536 TO 6 |