NSN 5950-00-019-3012 · NIIN 000193012 · FSC 5950
NO DASHES 5950000193012
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| ADAQ | BODY LENGTH | INCHES MINIMUM 4.515 AND INCHES MAXIMUM 4.546 |
| ADAT | BODY WIDTH | INCHES MINIMUM 2.984 AND INCHES MAXIMUM 3.015 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 3.437 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.484 AND INCHES MAXIMUM 3.515 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.109 AND INCHES MAXIMUM 2.140 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.164 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 416.00 |
| FEAT | SPECIAL FEATURES | MUST FUNCTION IN A LIQUID COOLED POWER SUPPLY PER FC 77 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 22 |