Home / MS parts / NSN 5925-00-816-6646
NSN 5925-00-816-6646  ·  NIIN 008166646  ·  FSC 5925
NO DASHES 5925008166646
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

31 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AXHRMOUNTING FACILITY TYPE AND QUANTITYSLOT 4
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 30.0 AND AMPERES DC 30.0
AKPXPOLE QUANTITY2
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 4.880
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.190
AJECBOSS HEIGHTINCHES NOMINAL 0.187
ADAUBODY HEIGHTINCHES NOMINAL 3.567
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 5.250
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT140.0
CPRQRESET METHODMANUAL
AAQLBODY STYLE
ABTDMOUNTING SLOT WIDTHINCHES NOMINAL 0.190
ADAQBODY LENGTHINCHES NOMINAL 6.310
ADATBODY WIDTHINCHES NOMINAL 2.750
TTQYTERMINAL TYPE AND QUANTITYCOMPRESSION 4
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MAXIMUM AT 200 PCT 120.000
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0 AND AC 250.0
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.375
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 40.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 10000.0 AND DC 5000.0
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE

Supersedes