FILTER,BAND PASS

Filters and Networks

Technical characteristics

23 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADAUBODY HEIGHTINCHES MAXIMUM 2.190
ABKWOVERALL HEIGHTINCHES MINIMUM 2.670
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 2
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 99.30 AND KILOHERTZ BLANK 99.77 AND KILOHERTZ BLANK 100.23 AND KILOHERTZ BLANK 100.78
CQJXNOMINAL THREAD SIZEINCHES 0.138
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 99.775 AND KILOHERTZ BLANK 100.225
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION NOMINAL BLANK 55.0 AND NOMINAL BLANK 3.0
STYLSTYLE DESIGNATOR
ADAQBODY LENGTHINCHES MAXIMUM 4.000
ADATBODY WIDTHINCHES MINIMUM 1.310 AND INCHES MAXIMUM 1.370
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 2
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 3.8
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 1
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 600.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE-RESISTANCE BLANK
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AHASLOAD IMPEDANCE PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 27.0
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 500.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 27.0
AFGAOPERATING TEMP RANGECELSIUS -30.0 TO 55.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 100.0