NSN 5970-01-084-3594 · NIIN 010843594 · FSC 5970
NO DASHES 5970010843594
In Stock
INSULATION SLEEVING,ELECTRICAL
Electrical Insulators and Insulating Materials
Application: MRAP - COUGAR CAT1 A2; MRAP - COUGAR CAT2 A2
Technical characteristics
14 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJH | TEMP RATING | CELSIUS -70.0 AND CELSIUS 121.0 |
| ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
| AFZL | EXPANDED INSIDE DIAMETER | INCHES MINIMUM 0.625 |
| AFZM | RECOVERED INSIDE DIAMETER | INCHES MAXIMUM 0.357 |
| AFZN | RECOVERED WALL THICKNESS | INCHES MINIMUM 0.037 AND INCHES MAXIMUM 0.067 |
| AGAU | HEAT SHRINKAGE RATING IN PERCENT | 42.9 |
| AGAV | END ITEM IDENTIFICATION | MRAP - COUGAR CAT1 A2; MRAP - COUGAR CAT2 A2 |
| CQBC | MINIMUM TENSILE STRENGTH | POUNDS PER SQUARE INCH 1500 |
| FEAT | SPECIAL FEATURES | RUBBER,POLYCHLOROPRENE,MIL-DTL-23053/1,CLASS 2 |
| FLEX | FLEXIBILITY | FLEXIBLE |
| HUES | COLOR | BLACK |
| STYL | STYLE DESIGNATOR | |
| UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | VOLTS PER MIL /0.001 INCH/ 300.0 |
Supersedes
This item replaces cancelled NIINs 011662199 · 011838661. An older drawing citing one of those numbers resolves here.