NSN 5925-00-877-2750  ·  NIIN 008772750  ·  FSC 5925
NO DASHES 5925008772750
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

35 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AFJNFRAGILITY FACTORMODERATELY RUGGED
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.740 AND INCHES MAXIMUM 2.760
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MINIMUM 3.709 AND INCHES MAXIMUM 3.729
ADATBODY WIDTHINCHES MINIMUM 2.021 AND INCHES MAXIMUM 2.041
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 3.053 AND INCHES MAXIMUM 3.073
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 3.239
AKPXPOLE QUANTITY2
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 4
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 5000.0
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 150.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 30.0
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRWACTUATOR FUNCTIONTRIP-RESET
MATTMATERIALCASE PLASTIC
AJECBOSS HEIGHTINCHES MINIMUM 0.146 AND INCHES MAXIMUM 0.166
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.500 AND MAXIMUM AT 200 PCT 8.000