Home / MS parts / NSN 5915-00-451-6097
NSN 5915-00-451-6097  ·  NIIN 004516097  ·  FSC 5915
NO DASHES 5915004516097
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

24 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 500.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 800.0
ADAUBODY HEIGHTINCHES MAXIMUM 0.780
AFGAOPERATING TEMP RANGECELSIUS -30.0 TO 85.0
AFSVAVERAGE LIFE RATING IN HOURS2000.0
PRMTPRECIOUS MATERIALGOLD
STYLSTYLE DESIGNATOR
TESTTEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 18876-10682611
FEATSPECIAL FEATURESUNPACKAGED UNIT WEIGHT: GM30.000
PMLCPRECIOUS MATERIAL AND LOCATIONGOLD TER-INALS
CQRGBODY MATERIALMETAL
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 793.50 AND HERTZ BLANK 806.50
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 40.0 AND MAXIMUM BLANK 3.0
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 2
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 787.50 AND HERTZ BLANK 793.50 AND HERTZ BLANK 806.50 AND HERTZ BLANK 812.50
ADAQBODY LENGTHINCHES MAXIMUM 1.175
AHASLOAD IMPEDANCE PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 5.0
AKNAINCLOSURE TYPEENCASED
ADATBODY WIDTHINCHES MAXIMUM 0.780
ABKWOVERALL HEIGHTINCHES MAXIMUM 1.080
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 4
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 4.0