NSN 5925-00-423-2791 · NIIN 004232791 · FSC 5925
NO DASHES 5925004232791
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 60.0 |
| AKPX | POLE QUANTITY | 1 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION FAHRENHEIT NOMINAL 77.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 24.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.125 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.875 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION INSTANTANEOUS AND TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.375 |
| CPRQ | RESET METHOD | AUTOMATIC |
| ZZZT | NONDEFINITIVE SPEC/STD DATA | TYPE II AND GROUP B AND CLASS 2 |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 2 |
| MATT | MATERIAL | CASE PLASTIC |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION NOMINAL AT 125 PCT 300.000 AND NOMINAL AT 250 PCT 20.000 |