NSN 5915-01-023-9816 · NIIN 010239816 · FSC 5915
NO DASHES 5915010239816
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
50 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 9.500 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 9.000 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 7.060 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 7.060 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES MINIMUM 0.218 AND INCHES MAXIMUM 0.224 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 8.125 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 6.125 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 78.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 60.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 25.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 25.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 32.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 32.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 25.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 2.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 2.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 2.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION MILLIVOLTS DC 4TH RADIO INTERFERENCE 500.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION MILLIVOLTS DC 5TH RADIO INTERFERENCE 500.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 35.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 6 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION THREADED STUD INPUT 5 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION THREADED STUD GROUND 2 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD OUTPUT 5 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 150.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS DC 4TH RADIO INTERFERENCE 150.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0 |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | VOLTS AT SEA LEVEL 600.0 |
| STYL | STYLE DESIGNATOR |