NSN 2920-00-585-9859 · NIIN 005859859 · FSC 2920
NO DASHES 2920005859859
In Stock
REGULATOR,ENGINE GENERATOR
Engine Electrical System Components, Nonaircraft
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
| ANYR | CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
| AARA | TERMINAL QUANTITY | 3 |
| ANYS | CUT-IN VOLTAGE RATING | MINIMUM 11.8 AND MAXIMUM 13.5 |
| ANYJ | CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
| ANPP | OUTPUT VOLTAGE RATING IN VOLTS | MINIMUM 13.8 AND MAXIMUM 14.8 |
| ANYC | SYSTEM VOLTAGE RATING | 12.0 |
| ANYD | SYSTEM GROUND POLARITY | NEGATIVE |
| ANYE | VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |
| CSCF | TERMINAL TYPE | LOCATION NOT OTHERWISE SPECIFIED SCREW |
| ADER | MOUNTING STYLE | |
| ADNZ | DISTANCE BETWEEN HOLES ALONG WIDTH | INCHES NOMINAL 1.500 |
| ANYP | OUTPUT CURRENT RATING IN AMPS | MINIMUM 23.0 AND MAXIMUM 27.0 |
| APAK | CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH | INCHES NOMINAL 5.060 |
| CBBL | FEATURES PROVIDED | SHOCK MOUNT(S) |
| ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FUNGUS RESISTANT |
| ANZE | TERMINAL ENCASEMENT | NOT ENCASED |
| ABTB | MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.278 |
| ANYK | CURRENT REGULATOR UNIT QUANTITY | 1 |
Supersedes
This item replaces cancelled NIINs 008517543 · 008340931 · 009143075. An older drawing citing one of those numbers resolves here.