NSN 5995-01-194-3402 · NIIN 011943402 · FSC 5995
NO DASHES 5995011943402
In Stock
CABLE ASSEMBLY,RADIO FREQUENCY
Cable, Cord, and Wire Assemblies: Communication Equipment
Application: PATERIOT MISSILE BATTERY
Technical characteristics
12 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJU | OVERALL LENGTH | INCHES 9.000 |
| AAPP | ELECTRICAL RESISTANCE | OHMS IMPEDANCE 50.00 |
| ABFF | FURNISHED ITEMS | CONNECTOR |
| ABJH | TEMP RATING | CELSIUS -45.6 AND CELSIUS 71.0 |
| AGAV | END ITEM IDENTIFICATION | PATERIOT MISSILE BATTERY |
| ALBY | USAGE DESIGN | MISSILE |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY, RADIO FREQUENCY |
| FEAT | SPECIAL FEATURES | FIRST PLUG: N SERIES PLUG, STRAIGHT WITH HEX COUPLING NUT: MATING DIMENSIONS SHALL COMPLY WITH MIL-C-39012/1, FIGURE 2; CONNECTOR SHALL BE SILVER PLATED BRASS OR CORROSION RESISTANT STEEL, PASSIVATED AND CENTER CONTACT SHALL HAVE FINISH I/A/W THE REQUIREMENTS OF MIL-C-39012; CONNECTOR SHALL BE SUPPLIED WITH 1 GASKET, SILICONE RUBBER, IMPREGNATED WITH SILVER RELATED PARTICLES; DUROMETER 75 + OR - 5, SHORE A; SECOND PLUG: SMA SERIES PLUG, STRAIGHT: MATING DIMENSIONS SHALL COMPLY WITH MIL-C-39012/55, FIGURE 3; BODY SHALL BE GOLD PLATED; COUPLING NUT SHALL BE PASSIVATED CORROSION RESISTANT STEEL AND CENTER CONTACT SHALL HAVE FINISH I/A/W THE REQUIREMENTS OF MIL-C-39012 |
| PMLC | PRECIOUS MATERIAL AND LOCATION | GOLD LUGS AND SILVER LUGS |
| PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
| SPCL | SPECIAL TEST FEATURES | UNIT WEIGHT: .062LBS; INSERTION LOSS: 0.3 (MAX);OPERATING FREQUENCY RANGE: 5 GIGAHERTZ TO 6 GIGAHERTZ;R.F. LEAKAGE: MINUS 60 DECIBELS PER FOOT MINIMUM; VOLTAGE STANDING WAVE RATIO (VSWR): 1.25:1 MAXIMUM WHEN TERMINATED IN A MATCHED LOAD; OPERATING VOLTAGE: 2,000 VOLTS RMS MAXIMUM;CAPACITANCE: 29.2 PICOFARADS MAXIMUM PER FOOT;DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL: 1,500 VOLTS RMS; CABLE BEND RADIUS: 1.5" MINIMUM; CABLE RETENTION: PER MIL-C-39012, 20LBS MINIMUM; SHOCK TEST PER MIL-STD-202, METHOD 213, TEST CONDITION K; VIBRATION PER MIL-STD-202, METHOD 204, TEST CONDITION A; SALT SPRAY PER MIL-STD-202, METHOD 101, TEST CONDITION B |
| STYL | STYLE DESIGNATOR |