Home / MS parts / NSN 5925-00-785-2675
NSN 5925-00-785-2675  ·  NIIN 007852675  ·  FSC 5925
NO DASHES 5925007852675
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

30 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
ABXDBUSHING LENGTHINCHES NOMINAL 0.469
ADAQBODY LENGTHINCHES MAXIMUM 1.137
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.812
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
AAQLBODY STYLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 3.0
TESTTEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 99193-379868
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYSCREW 2
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0
ADATBODY WIDTHINCHES MAXIMUM 0.750
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.704
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPRPULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MAXIMUM 300.000
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.469
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.040 AND MAXIMUM AT 200 PCT 20.000
MATTMATERIALCASE PLASTIC
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 28.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 6.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT

Supersedes

This item replaces cancelled NIINs 009130572 · 011255718. An older drawing citing one of those numbers resolves here.