NSN 6120-01-701-1520 · NIIN 017011520 · FSC 6120
NO DASHES 6120017011520
In Stock
TRANSFORMER,POWER
Transformers: Distribution and Power Station
Application: 4940-01-682-2525
Technical characteristics
13 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| AGAV | END ITEM IDENTIFICATION | 4940-01-682-2525 |
| CBBL | FEATURES PROVIDED | ROHS DIRECTIVE COMPLIANCE |
| FEAT | SPECIAL FEATURES | OPERATING TEMPERATURE: -20 DEG C TO +50 DEG C; OUTPUT FREQUENCY: 50-480HZ; TURNS RATIO MEASUREMENT METHODS: 50,000 DOWN-100 UP; MAX INDUCED VOLTAGE: 125V; WEIGHT: 14 POUNDS; RUGGEDIZED CASE WITH FOLD OUT FEET; CANVAS CARRYING BAG FOR LEADS AND ACCESSORIES |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 12.0 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 16.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 8.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS MINIMUM 1.0 AND AC VOLTS MAXIMUM 48.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | CABLE W/CONNECTOR 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY OUTPUT AMPERES AC MAXIMUM 1.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS MINIMUM 90.0 AND AC VOLTS MAXIMUM 264.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |