NSN 5640-01-146-1890 · NIIN 011461890 · FSC 5640
NO DASHES 5640011461890
In Stock
INSULATION PIPE FITTING COVERING
Wallboard, Building Paper, and Thermal Insulation Materials
Technical characteristics
8 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARM | LAYER QUANTITY | 3 |
| AARN | FABRICATION METHOD | COMPRESSED |
| AARQ | FLAMMABILITY RATING | NOT RATED |
| AARU | INSULATION THICKNESS | INCHES MINIMUM 0.320 AND INCHES MAXIMUM 0.440 |
| AARY | END CONNECTION FITTING DESIGN ACCOMMODATED | WELDED FITTING |
| FEAT | SPECIAL FEATURES | LENGTH 15.760 IN. MIN AND 15.880 IN. MAX; INSIDE DIAMETER 4.500 IN. MIN AND 4.560 IN. MAX |
| MATT | MATERIAL | LOCATION NOT OTHERWISE SPECIFIED SILICA FIBER |
| MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | LOCATION NOT OTHERWISE SPECIFIED ASSN STD SINGLE MATERIAL RESPONSE A-S 3680 |