Home / MS parts / Electrical & Electronic Components / NSN 5930-01-316-1752
NSN 5930-01-316-1752  ·  NIIN 013161752  ·  FSC 5930
NO DASHES 5930013161752
In Stock

SWITCH,ROTARY

Switches

Technical characteristics

28 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAJDTHREAD CLASS2B
ABFEHAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONSHOCK RESISTANT
ABHPOVERALL LENGTHINCHES NOMINAL 8.063
ABKWOVERALL HEIGHTINCHES NOMINAL 3.688
ABMKOVERALL WIDTHINCHES NOMINAL 3.812
AEBVUNTHREADED MOUNTING HOLE DIAMETERSECOND MOUNTING FACILITY INCHES NOMINAL 0.312
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERSSECOND MOUNTING FACILITY INCHES NOMINAL 3.812
AFBHINDIVIDUAL SECTION QUANTITY12
AJZESWITCH CONTACT BASIC DESIGNNONPILE-UP NONSYMMETRICAL
ALAQMOUNTING FACILITY CIRCLE RADIUSFIRST MOUNTING FACILITY INCHES NOMINAL 1.609
AXGYMOUNTING METHODFIRST MOUNTING FACILITY BRACKET(S) AND THREADED HOLE(S)
AXGYMOUNTING METHODSECOND MOUNTING FACILITY BRACKET(S) AND UNTHREADED HOLE(S)
CBBLFEATURES PROVIDEDACTUATOR KNOB
CMLPTHREAD QUANTITY PER INCH20
CQJXNOMINAL THREAD SIZEFIRST MOUNTING FACILITY INCHES 0.250
CQMKCONTACT VOLTAGE RATING IN VOLTS500.0
CQYJMOUNTING FACILITY PATTERNFIRST MOUNTING FACILITY FOUR POSITION CIRCULAR
CQYJMOUNTING FACILITY PATTERNSECOND MOUNTING FACILITY TWO POSITION IN-LINE
CRJHSWITCH ACTUATOR INDEXING POSITION QUANTITY2
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CSCFTERMINAL TYPETAB W/SCREW
CSHWCONTACT SWITCHING ACTIONEACH SECTION PERIPHERY BREAKS BEFORE MAKES
CSLCSWITCH ACTUATOR POSITIONING INCREMENTSINGLE ACTUATOR DEGREES 90.0
CTDNSWITCH ACTUATOR STOP DEVICE TYPESINGLE ACTUATOR ADJUSTABLE STOP
CTHFCONTACT LOAD CURRENT RATINGAC AT SEA LEVEL AMPERES RESISTIVE LOAD 30.0
FEATSPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L04177; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY
STYLSTYLE DESIGNATOR
THSDTHREAD SERIES DESIGNATORFIRST MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)