NSN 5985-00-807-3723 · NIIN 008073723 · FSC 5985
NO DASHES 5985008073723
In Stock
COUPLER,DIRECTIONAL
Antennas, Waveguides, and Related Equipment
Technical characteristics
14 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ZZZV | FSC APPLICATION DATA | ANTENNAS, WAVEGUIDES, AND RELATED EQUIPMENT |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.200 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.687 |
| ALBY | USAGE DESIGN | TERMINAL FITTING MAIN LINE AND SECONDARY LINE |
| ANKZ | RADIO FREQUENCY RATING | MEGAHERTZ MINIMUM 50.0 AND MEGAHERTZ MAXIMUM 12000.0 |
| AXEB | IDENTIFYING NUMBER | TERMINAL FITTING TYPE NO. N; TYPE NO. N; TYPE NO. BNC |
| PMLC | PRECIOUS MATERIAL AND LOCATION | SILVER EXTERNAL SURFACES |
| PRMT | PRECIOUS MATERIAL | SILVER |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 2.700 |
| BGPX | POWER LOSS IN DECIBELS | 0.2 |
| BGPZ | TERMINAL FITTING CONTROLLING AGENCY | AN |
| FEAT | SPECIAL FEATURES | IMPEDANCE 50.0 OHMS; TEMPERATURE RANGE MINUS 55.0 DEG TO PLUS 150.0 DEG C; AVERAGE POWER 500.0 WATTS, PEAK POWER 5.0 KW |
| APQB | UNIT TYPE | TRANSMISSION LINE |
| APGF | DESIGN TYPE | UNIDIRECTIONAL |
Supersedes
This item replaces cancelled NIINs 000224245 · 009180414. An older drawing citing one of those numbers resolves here.