| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 20.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 0.250 |
| ADAV | OVERALL DIAMETER | INCHES MAXIMUM 0.700 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 105.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 1 |
| AXGY | MOUNTING METHOD | SINGLE GROUP TERMINAL AND THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.112 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC NOMINAL 200.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC NOMINAL 6.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 56.56 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 848.40 |
| FEAT | SPECIAL FEATURES | ADDITIONAL OPERATING CONDITION WITH PRIMARY WINDING 6.6 VAC AT 3 AMPS,20 KHZ; SECONDARY WINDING,100 VAC AT 0.100 AMPS |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 6 |