Home / MS parts / NSN 5925-00-074-2031
NSN 5925-00-074-2031  ·  NIIN 000742031  ·  FSC 5925
NO DASHES 5925000742031
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 2
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 4.0 AND AMPERES DC 4.0
PRPYPROPRIETARY CHARACTERISTICSPACS
PRMTPRECIOUS MATERIALSILVER
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.081
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER CONTACT SURFACES
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
AKPXPOLE QUANTITY1
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.205 AND INCHES MAXIMUM 0.295
ADAQBODY LENGTHINCHES MINIMUM 1.127 AND INCHES MAXIMUM 1.147
ADATBODY WIDTHINCHES MAXIMUM 0.750
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 120.0 AND DC 30.0
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.469
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.700 AND MAXIMUM AT 200 PCT 1.500
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVIBRATIONPROOF AND SHOCKPROOF
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.843
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0 AND DC 6000.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
AFJNFRAGILITY FACTORMODERATELY RUGGED
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.690 AND INCHES MAXIMUM 0.710