MRCRequirementValue
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 10.0
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS MAXIMUM 85.0
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 9.3
CTTCTHREAD TOLERANCE CLASSEXTERNAL 32A
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYCIRCUIT BREAKER
FREQFREQUENCY IN HERTZ400.0
PRPYPROPRIETARY CHARACTERISTICSPACS
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 6
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1 AND THREADED HOLE(S) 3
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.500 AND INCHES 0.138
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 150 PCT 5.0 AND MAXIMUM AT 150 PCT 70.0
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDWATERTIGHT
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
AGAVEND ITEM IDENTIFICATIONPATRIOT
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.040
AKPXPOLE QUANTITY3
ABXDBUSHING LENGTHINCHES NOMINAL 0.625
ADAQBODY LENGTHINCHES NOMINAL 2.490
ADATBODY WIDTHINCHES NOMINAL 2.265
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.515 AND INCHES NOMINAL 0.156
CPRQRESET METHODMANUAL
AAQLBODY STYLE
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0