Home / MS parts / NSN 5925-01-717-2293
NSN 5925-01-717-2293  ·  NIIN 017172293  ·  FSC 5925
NO DASHES 5925017172293
In Stock

CIRCUIT BREAKER

Circuit Breakers

Application: DAU 7-3-1/LHA CLASS MACHINERY CONTROL SYSTEM

Technical characteristics

27 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AGAVEND ITEM IDENTIFICATIONDAU 7-3-1/LHA CLASS MACHINERY CONTROL SYSTEM
AKPXPOLE QUANTITY1
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 10.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL-MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION INSTANTANEOUS
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AAQLBODY STYLE
ABKWOVERALL HEIGHTINCHES NOMINAL 3.46
ADAQBODY LENGTHINCHES NOMINAL 2.9
ADATBODY WIDTHINCHES NOMINAL 0.69
ADAUBODY HEIGHTINCHES NOMINAL 3.46
CTJSUNPACKAGED UNIT WEIGHTGRAMS NOMINAL 125.0
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYMINIATURE CIRCUIT BREAKER
FEATSPECIAL FEATURESHOUSING MATERIAL: INSULATION GROUP II, RAL 7035; DUAL TERMINAL; TRIP CURVE C
MATTMATERIALCASE PLASTIC
PRPYPROPRIETARY CHARACTERISTICSPACS
TTQYTERMINAL TYPE AND QUANTITYBUS BAR 1 AND WIRE LEAD 2
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SHUNT TRIP
CQQCTRIP RELEASE DUTY CYCLESINGLE LOCATION CONTINUOUS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS MINIMUM -25.0 AND CELSIUS MAXIMUM 55.0
CRTKSWITCH TERMINAL TYPEBUS BAR
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 3.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 250.0
CBBLFEATURES PROVIDEDROHS DIRECTIVE COMPLIANCE AND TRIP INDICATOR
AXHRMOUNTING FACILITY TYPE AND QUANTITYDIN RAIL 1 AND CLIP 1