NSN 5840-01-334-9395 · NIIN 013349395 · FSC 5840
NO DASHES 5840013349395
In Stock
RADAR SET
Radar Equipment, Except Airborne
Application: RADAR SET,AN/FPS-124
Technical characteristics
14 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACYN | AC VOLTAGE RATING | LOCATION NOT OTHERWISE SPECIFIED VOLTS MINIMUM 120.0 AND VOLTS MAXIMUM 208.0 |
| ACYR | DC VOLTAGE RATING | LOCATION NOT OTHERWISE SPECIFIED VOLTS NOMINAL 33.75 |
| ACZB | FREQUENCY RATING | LOCATION NOT OTHERWISE SPECIFIED HERTZ NOMINAL 60.0 |
| AGAV | END ITEM IDENTIFICATION | RADAR SET,AN/FPS-124 |
| AKWA | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | RADAR SET |
| AKWB | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | AN/FPS-124 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| AMKF | TRANSMITTED SIGNAL FREQUENCY RATING | GIGAHERTZ MINIMUM 1.215 AND GIGAHERTZ MAXIMUM 1.400 |
| AMKN | RECEIVED SIGNAL FREQUENCY RATING | GIGAHERTZ MINIMUM 1.215 AND GIGAHERTZ MAXIMUM 1.400 |
| AMQY | INSTALLATION DESIGN | FIXED |
| FAAZ | PHASE | LOCATION NOT OTHERWISE SPECIFIED THREE |
| FEAT | SPECIAL FEATURES | RADAR USES DISTRIBUTED PHASED ARRAY; LOCAL CONTROLLING FUNCTION HOUSED WITH SHELTER LEVEL EQUIPMENT; REMOTE CONTROLLING FUNCTION HOUSED AT LOCATION SEPARATE FROM RADAR BUT LINKED VIA SATELLITE COMMUNCATIONS; TOWER HOUSING THE SHELTER FOR SHELTER LEVEL EQUIPMENT IS NOT PART OF THE RADAR |
| FTLD | FUNCTIONAL DESCRIPTION | PHASED ARRAY L-BAND SEARCH RADAR DESIGNED FOR UNATTENDED OPERATION AT REMOTE LOCATIONS; COMPUTER CONTROLLED RADAR; INCLUDES CIRCUITRY TO FORWARD TRACK DATA TO PROPER RADAR CONTROL CENTER |
| SUPP | SUPPLEMENTARY FEATURES | TRANSMIT POWER 7.9 KW PEAK; RADAR RANGE 2-70 NMI; AZIMUTH 360 DEG; ELEVATION -10 TO +20 DEG; PRF 1066 PPS AVG; BANDWIDTH 4 MHZ; INCLUDES 1 RF SWITCHING GP,1 RADAR SET SUBASSY,1 ELECTRONIC SWITCH,1 SIGNAL DATA CONVERTER,1 MEMORY UNIT,2 COMM. MODEM,1 BAND PASS FILTER,1 SIGNAL PROCESSOR,1 DIGITAL TO DIGITAL CONVERTER,2 RADAR COMPUTER,1 RADOME,72 ANTENNA,36 RF AMPLLIFIER,72 RF TRANSMISSION LINE SWITCH,8 POWER SUPPLY,3 RECEIVER,1 ANTENNA GROUP,1 INTERCONNECTING ELEC. CONTROL RACK GP,1 POWER SUPPLY GP,2 CONTROLLER-MONITOR GROUP |