NSN 6130-01-216-9168 · NIIN 012169168 · FSC 6130
NO DASHES 6130012169168
In Stock
POWER SUPPLY ASSEMBLY
Converters, Electrical, Nonrotating
Application: BMEWS RADAR UPGRADE
Technical characteristics
28 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 22.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 5.250 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 19.000 |
| AGAV | END ITEM IDENTIFICATION | BMEWS RADAR UPGRADE |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | FOURTH OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | SECOND OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | FIRST OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | THIRD OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | THIRD OPERATING POWER RQMT AC VOLTS MINIMUM 98.0 AND AC VOLTS MAXIMUM 264.0 |
| APNX | INPUT VOLTAGE RATING | FOURTH OPERATING POWER RQMT AC VOLTS MINIMUM 98.0 AND AC VOLTS MAXIMUM 264.0 |
| APNX | INPUT VOLTAGE RATING | FIRST OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 132.0 |
| APNX | INPUT VOLTAGE RATING | SECOND OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 132.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS MINIMUM 4.5 AND DC VOLTS MAXIMUM 6.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS MINIMUM 4.5 AND DC VOLTS MAXIMUM 6.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS MINIMUM 20.0 AND DC VOLTS MAXIMUM 25.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS MINIMUM 20.0 AND DC VOLTS MAXIMUM 25.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 440.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 440.0 |
| APTQ | INPUT FREQUENCY RATING | THIRD OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| APTQ | INPUT FREQUENCY RATING | FOURTH OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 440.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -0.0 TO 70.0 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES MINIMUM 6.5 AND DC AMPERES MAXIMUM 13.0 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES MINIMUM 6.5 AND DC AMPERES MAXIMUM 13.0 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES MINIMUM 9.6 AND DC AMPERES MAXIMUM 24.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES MINIMUM 9.6 AND DC AMPERES MAXIMUM 24.0 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |