Home / MS parts / NSN 5915-00-491-6324
NSN 5915-00-491-6324  ·  NIIN 004916324  ·  FSC 5915
NO DASHES 5915004916324
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

25 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 55.0
AFSVAVERAGE LIFE RATING IN HOURS10000.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 2.425
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 2.365 AND KILOHERTZ BLANK 2.485
STYLSTYLE DESIGNATOR
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 2
AFGAOPERATING TEMP RANGECELSIUS -54.0 TO 71.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 1.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK
ADAQBODY LENGTHINCHES NOMINAL 1.000
ADATBODY WIDTHINCHES NOMINAL 1.000
ADAUBODY HEIGHTINCHES NOMINAL 1.375
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 1.212 AND KILOHERTZ BLANK 2.365 AND KILOHERTZ BLANK 2.485 AND KILOHERTZ BLANK 4.850
CQJXNOMINAL THREAD SIZEINCHES 0.112
ABKWOVERALL HEIGHTINCHES NOMINAL 1.750
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 40.0 AND MAXIMUM BLANK 6.0
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGEVOLTS AT SEA LEVEL 500.0
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION WIRE HOOK GROUND 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION WIRE HOOK OUTPUT 1
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 1.0
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 4.0
AKNAINCLOSURE TYPEENCASED
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION WIRE HOOK INPUT 1