NSN 5945-00-556-5010 · NIIN 005565010 · FSC 5945
NO DASHES 5945005565010
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| APNP | DUTY TYPE | CONTINUOUS |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.250 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.688 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY TRIANGLE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 4.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 8 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 3 |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.112 |
| AAJD | THREAD CLASS | 2A |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.020 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING KILOHMS NOMINAL 8.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.020 |
Supersedes
This item replaces cancelled NIINs 000278514 · 005811982 · 006138494 · 006819690 · 008089873 · 008436539. An older drawing citing one of those numbers resolves here.