NSN 5915-01-052-3423 · NIIN 010523423 · FSC 5915
NO DASHES 5915010523423
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
52 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.670 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.750 |
| ADAT | BODY WIDTH | INCHES NOMINAL 4.000 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 2.170 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 4.250 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 3.500 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| AFSV | AVERAGE LIFE RATING IN HOURS | 1000.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 400.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 3.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 3.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 3.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 1.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SIXTH FUNCTION 6TH RADIO INTERFERENCE 1.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 3.5 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 0.28 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 0.28 |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 96214 |
| AHBP | INPUT TERMINAL IDENTIFICATION | MS3122E20-16P |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 25.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 8 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 28.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 115.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| CRST | BODY SURFACE TREATMENT | TIN |
| CTJS | UNPACKAGED UNIT WEIGHT | POUNDS NOMINAL 4.100 |
| STYL | STYLE DESIGNATOR |