NSN 5910-00-996-0724 · NIIN 009960724 · FSC 5910
NO DASHES 5910009960724
In Stock
CAPACITOR,FIXED,MICA DIELECTRIC
Capacitors
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES NOMINAL 0.425 |
| CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION -200.0 TO 200.0 |
| CRTP | TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -5.00 TO 5.00 |
| AAQL | BODY STYLE | |
| CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | MEGOHMS 5000.0 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.360 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 0.194 AND INCHES MAXIMUM 0.256 |
| CQJJ | NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 150.0 |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 500.0 |
| MATT | MATERIAL | CASE PLASTIC |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5 |
| TTQY | TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | INCHES MINIMUM 1.000 |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | MEGOHMS 100000.0 |
| CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0050 |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
| CQBQ | CAPACITANCE VALUE PER SECTION | PICOFARADS SINGLE SECTION 12.000 |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | |
| ADAU | BODY HEIGHT | INCHES NOMINAL 0.130 |
Supersedes
This item replaces cancelled NIIN 007285179. An older drawing citing one of those numbers resolves here.