NSN 6240-00-580-0666 · NIIN 005800666 · FSC 6240
NO DASHES 6240005800666
In Stock
LAMP,GLOW
Electric Lamps
Application: TICONDEROGA CLASS CG (47); LOS ANGELES CLASS SSN (688); TARAWA CLASS LHA; OLIVER PERRY CLASS FFG; EMORY S. LAND CLASS AS; SPRUANCE CLASS DD (963); KNOX CLASS FF; MISSILE, ALL-WEATHER ANTI-SHIP, HARPOON (AGM-84); FORRESTAL CLASS CV; SAFEGUARD CLASS ARS
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AFSV | AVERAGE LIFE RATING IN HOURS | 25000.0 |
| BDWW | WATTAGE RATING | WATTS 0.250 |
| CRPS | BASE STYLE | |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 0.750 |
| AFSQ | CIRCUIT VOLTAGE RATING IN VOLTS | MINIMUM 105.000 AND MAXIMUM 125.000 |
| CTNB | RESISTOR RATING AND LOCATION | KILOHMS EXTERNAL 30.000 |
| AGDV | EMITTED LIGHT CHARACTERISTIC | RED |
| CSJW | BULB DESIGNATOR | T-2 |
| CTGF | FILLING GAS TYPE | NEON |
| AFSC | WIRE LEAD LENGTH | INCHES NOMINAL 2.000 |
| AFSM | LIGHT INTENSITY LEVEL | HIGH |
| CWBF | RATED AVERAGE LIFE | HOURS |
| CTLD | GAS STRIKING VOLTAGE RATING IN VOLTS AND CURRENT TYPE | SECOND VOLTAGE DC MAXIMUM 135.0 |
| FEAT | SPECIAL FEATURES | LAMP P/N C2A W/FROSTED FINISH BULB |
| CTLD | GAS STRIKING VOLTAGE RATING IN VOLTS AND CURRENT TYPE | FIRST VOLTAGE AC MAXIMUM 95.0 |
| CRSK | BULB STYLE | |
| AGAV | END ITEM IDENTIFICATION | TICONDEROGA CLASS CG (47); LOS ANGELES CLASS SSN (688); TARAWA CLASS LHA; OLIVER PERRY CLASS FFG; EMORY S. LAND CLASS AS; SPRUANCE CLASS DD (963); KNOX CLASS FF; MISSILE, ALL-WEATHER ANTI-SHIP, HARPOON (AGM-84); FORRESTAL CLASS CV; SAFEGUARD CLASS ARS |
Supersedes
This item replaces cancelled NIIN 010105478. An older drawing citing one of those numbers resolves here.