NSN 6130-01-259-0375 · NIIN 012590375 · FSC 6130
NO DASHES 6130012590375
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: TRANS MODULE STATION
Technical characteristics
42 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 10.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.750 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 9.000 |
| ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
| AGAV | END ITEM IDENTIFICATION | TRANS MODULE STATION |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 15000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 103.5 AND AC VOLTS MAXIMUM 129.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 7.1 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 17.0 |
| APPA | OUTPUT VOLTAGE RATING | NINTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | SEVENTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | TENTH POWER OUTPUT DC VOLTS NOMINAL -5.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT DC VOLTS NOMINAL 7.1 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL 7.1 |
| APPA | OUTPUT VOLTAGE RATING | SIXTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | EIGHTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0 |
| APTQ | INPUT FREQUENCY RATING | THIRD ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.5 AND HERTZ MAXIMUM 52.5 |
| APTQ | INPUT FREQUENCY RATING | SECOND ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 57.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -10.0 TO 55.0 |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWGH | OUTPUT CURRENT RATING | FIFTH POWER OUTPUT DC AMPERES NOMINAL 7.0 |
| CWGH | OUTPUT CURRENT RATING | NINTH POWER OUTPUT DC AMPERES NOMINAL 2.3 |
| CWGH | OUTPUT CURRENT RATING | SEVENTH POWER OUTPUT DC AMPERES NOMINAL 2.3 |
| CWGH | OUTPUT CURRENT RATING | TENTH POWER OUTPUT DC AMPERES NOMINAL -0.1 |
| CWGH | OUTPUT CURRENT RATING | SIXTH POWER OUTPUT DC AMPERES NOMINAL 4.4 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES NOMINAL 7.0 |
| CWGH | OUTPUT CURRENT RATING | EIGHTH POWER OUTPUT DC AMPERES NOMINAL 2.3 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 1.9 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 7.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 3.7 |
| CWHF | OUTPUT CONNECTION QUANTITY | 13 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT TERMINAL STRIP |
| CWHT | INPUT CONNECTION QUANTITY | 2 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 72.0 |
| FEAT | SPECIAL FEATURES | NUCLEAR HARDENED ITEM |