NSN 5905-00-924-9264 · NIIN 009249264 · FSC 5905
NO DASHES 5905009249264
In Stock
RESISTOR,VARIABLE,WIRE WOUND,NON
Resistor
Technical characteristics
32 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 0.359 AND INCHES MAXIMUM 0.391 |
| ABWV | SHAFT DIAMETER | INCHES MINIMUM 0.080 AND INCHES MAXIMUM 0.100 |
| ABXF | SHAFT LENGTH | INCHES MINIMUM 0.030 AND INCHES MAXIMUM 0.050 |
| ADAQ | BODY LENGTH | INCHES MINIMUM 0.359 AND INCHES MAXIMUM 0.391 |
| ADAT | BODY WIDTH | INCHES MINIMUM 0.188 AND INCHES MAXIMUM 0.219 |
| ADAU | BODY HEIGHT | INCHES MINIMUM 0.359 AND INCHES MAXIMUM 0.391 |
| AEDX | SHAFT STYLE | |
| AEFD | ACTUATOR TYPE | SINGLE SHAFT |
| AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | INCHES NOMINAL 0.200 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 0.359 AND INCHES MAXIMUM 0.391 |
| ABTB | MOUNTING HOLE DIAMETER | INCHES MINIMUM 0.074 |
| ABTD | MOUNTING SLOT WIDTH | INCHES NOMINAL 0.074 |
| AAQL | BODY STYLE | |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 0.715 |
| CQCC | ELECTRICAL RESISTANCE PER SECTION | KILOHMS SINGLE SECTION 20.0 |
| CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | NOMINAL 9000.0 |
| CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | SINGLE SECTION -5.0 TO 5.0 |
| CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
| CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | SINGLE SECTION 70.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 3 |
| ABJT | TERMINAL LENGTH | INCHES NOMINAL 0.300 |
| CQTM | TERMINAL LOCATION | LOCATION NOT OTHERWISE SPECIFIED LEFT ADJACENT SIDE SINGLE ROW |
| CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION -50.0 TO 50.0 |
| CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | FREE AIR SINGLE SECTION 1.0 |
| AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | INCHES NOMINAL 0.360 |
| AKPV | MOUNTING FACILITY QUANTITY | 1 |
| AXGY | MOUNTING METHOD | TERMINAL AND UNTHREADED HOLE(S) |
| AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | INCHES NOMINAL 0.100 |
| CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | SINGLE SECTION 175.0 |
| AAPN | SECTION QUANTITY | 1 |
| CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | INCHES MINIMUM 0.090 AND INCHES MAXIMUM 0.110 |