NSN 5915-00-953-5121 · NIIN 009535121 · FSC 5915
NO DASHES 5915009535121
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED NOMINAL BLANK 60.0 AND NOMINAL BLANK 6.0 AND NOMINAL BLANK 6.0 AND NOMINAL BLANK 60.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.000 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 500.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 4.7 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.500 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.250 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 100.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB, SOLDER LUG OUTPUT 2 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 380.00 AND HERTZ BLANK 475.00 AND HERTZ BLANK 525.00 AND HERTZ BLANK 620.00 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.112 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.500 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| STYL | STYLE DESIGNATOR | |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 475.00 AND HERTZ BLANK 525.00 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 2 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 0.719 AND INCHES MAXIMUM 0.781 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.000 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 6.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 1.8 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE-RESISTANCE BLANK |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB, SOLDER LUG INPUT 2 |