Home / MS parts / Electrical & Electronic Components / NSN 5950-00-165-3694
NSN 5950-00-165-3694  ·  NIIN 001653694  ·  FSC 5950
NO DASHES 5950001653694
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

32 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.740 AND INCHES MAXIMUM 2.760
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.927 AND INCHES MAXIMUM 1.947
ABMKOVERALL WIDTHINCHES MINIMUM 2.220 AND INCHES MAXIMUM 2.280
ABTDMOUNTING SLOT WIDTHSINGLE GROUP INCHES MINIMUM 0.100 AND INCHES MAXIMUM 0.160
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
ACZDTRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
ACZFMAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT VOLT-AMPERE 446.5
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
ADAQBODY LENGTHINCHES MINIMUM 2.970 AND INCHES MAXIMUM 3.030
ADAUBODY HEIGHTINCHES MINIMUM 1.280 AND INCHES MAXIMUM 1.340
AEHZMAXIMUM OPERATING TEMPCELSIUS 155.0
AKNAINCLOSURE TYPEOPEN
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP BRACKET(S) AND SLOT
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 6
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 6.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 900.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 2.5
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 1.8
CRMJWINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 238.7
CRMJWINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 24.1
CRMJWINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 45.4
CRMJWINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 48.3
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 23.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 15.50
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 10.50
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 113.00 AND AC VOLTS MAXIMUM 195.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.50
FEATSPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS
TTQYTERMINAL TYPE AND QUANTITYWIRE LEAD 22