NSN 5915-00-824-5772 · NIIN 008245772 · FSC 5915
NO DASHES 5915008245772
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQJX | NOMINAL THREAD SIZE | INCHES 0.750 |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 25.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB W/SCREW INPUT 1 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 20.0 |
| CQRG | BODY MATERIAL | METAL |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 5.980 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 4.090 |
| ADAR | BODY OUTSIDE DIAMETER | INCHES MAXIMUM 1.560 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THIRD FUNCTION THREADED BUSHING 1 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 20.0 |
| STYL | STYLE DESIGNATOR | |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 125.0 AND VOLTS DC 1ST RADIO INTERFERENCE 400.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 125.0 AND VOLTS DC 2ND RADIO INTERFERENCE 400.0 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB W/SCREW OUTPUT 1 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |