NSN 5925-00-404-9035 · NIIN 004049035 · FSC 5925
NO DASHES 5925004049035
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
41 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MAXIMUM 0.906 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 6 |
| ABXD | BUSHING LENGTH | INCHES NOMINAL 0.332 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.562 |
| CPRH | CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | MANUAL |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.937 |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 0.500 AND MAXIMUM AT 200 PCT 9.000 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND MOISTURE RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.375 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 1.828 |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CTJS | UNPACKAGED UNIT WEIGHT | GRAMS NOMINAL 150.0 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39019 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 300.0 |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.687 |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-C-39019 TO 6 |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| AAQL | BODY STYLE | |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 6.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 240.0 |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 120.0 AND DC 50.0 |
| CRTK | SWITCH TERMINAL TYPE | PIN |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | AC 0.5 AND DC 0.5 |