NSN 5945-01-406-6943 · NIIN 014066943 · FSC 5945
NO DASHES 5945014066943
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
30 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.718 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.625 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.290 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.025 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.150 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 2 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 2 |
| APNA | WINDING DC RESISTANCE RATING | ALL WINDINGS OHMS NOMINAL 405.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY SLOTTED HOLE 3 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBBL | FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
| CBME | CUBIC MEASURE | CUBIC INCHES 2.272 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY TRIANGLE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 4 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | ALL WINDINGS MILLIAMPERES DC 75.0 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.015 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | SINGLE MOUNTING FACILITY INCHES MINIMUM 1.396 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | ALL WINDINGS VOLTS DC 25 DEG CELSIUS 28.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| FEAT | SPECIAL FEATURES | FAILURE RATE: 3.0 PERCENT PER 10,000 CYCLES |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-RF-83536 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 16 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-R-83536 TO 18 |