NSN 6130-01-178-3648 · NIIN 011783648 · FSC 6130
NO DASHES 6130011783648
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: AN/ALQ-117
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT |
| AGAV | END ITEM IDENTIFICATION | AN/ALQ-117 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 55000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS NOMINAL 115.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT DC VOLTS MINIMUM -14.0 AND DC VOLTS MAXIMUM -15.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS MINIMUM -4.0 AND DC VOLTS MAXIMUM -6.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS MINIMUM 4.0 AND DC VOLTS MAXIMUM 6.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS MINIMUM 13.5 AND DC VOLTS MAXIMUM 16.5 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ NOMINAL 400.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND INPUT TO CASE ISOLATION AND INPUT TO OUTPUT ISOLATION AND OUTPUT TO CASE ISOLATION |
| CWGH | OUTPUT CURRENT RATING | FIFTH POWER OUTPUT DC AMPERES NOMINAL -4.4 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 5.5 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 10.0 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES NOMINAL -0.4 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 4.0 |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 54.0 |
| FEAT | SPECIAL FEATURES | EACH UNIT PRODUCED SHALL BE BURN-ED IN FOR 72 HOURS UNTIL THE LAST 24 HOURS ARE FAILURE FREE |