| MRC | Requirement | Value |
|---|---|---|
| CPRW | ACTUATOR FUNCTION | TRIP W/SEPARATE RESET |
| AAQL | BODY STYLE | |
| AKPX | POLE QUANTITY | 3 |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 1.376 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.750 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.36 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.875 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, THREE-POLE, THREE PHASE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 2.0663 |
| CPRQ | RESET METHOD | MANUAL |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 1 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 2.5 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 120.0 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 6 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING 1 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.8 AND MAXIMUM AT 200 PCT 3.0 |
| ABXD | BUSHING LENGTH | INCHES NOMINAL 0.400 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.468 |