NSN 6120-01-107-9661 · NIIN 011079661 · FSC 6120
NO DASHES 6120011079661
In Stock
POWER SUPPLY
Transformers: Distribution and Power Station
Technical characteristics
13 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 4.500 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.900 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 3.000 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 10000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS NOMINAL 115.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 55.0 AND HERTZ MAXIMUM 420.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 60.0 |
| CWGH | OUTPUT CURRENT RATING | MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS DC AMPERES NOMINAL 0.2 |