Home / MS parts / NSN 5925-00-222-8263
NSN 5925-00-222-8263  ·  NIIN 002228263  ·  FSC 5925
NO DASHES 5925002228263
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADAQBODY LENGTHINCHES MAXIMUM 1.152
ADATBODY WIDTHINCHES MAXIMUM 0.750
CQJXNOMINAL THREAD SIZEINCHES 0.469
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 55.000
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 20.0 AND AMPERES DC 20.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 200.0 AND DC 28.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 5000.0 AND DC 5000.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.125
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER TER-INAL SURFACES
PRMTPRECIOUS MATERIALSILVER
PRPYPROPRIETARY CHARACTERISTICSPACS
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 2
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MAXIMUM 0.250
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.173 AND INCHES MAXIMUM 1.203
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.859
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1

Supersedes

This item replaces cancelled NIIN 005538802. An older drawing citing one of those numbers resolves here.