NSN 5985-00-545-4806 · NIIN 005454806 · FSC 5985
NO DASHES 5985005454806
In Stock
WAVEGUIDE ASSEMBLY
Antennas, Waveguides, and Related Equipment
Technical characteristics
30 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQQF | OPERATING PRESSURE | POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 10.0 |
| MATT | MATERIAL | SINGLE TUBING SEGMENT ALUMINUM ALLOY |
| ACJL | BEND ANGLE IN DEG | 90.0 |
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| AHRV | TUBING WALL CONSTRUCTION STYLE | |
| AHRW | TUBING TWIST TYPE | SINGLE TUBING SEGMENT STRAIGHT TWIST |
| AHRX | TUBING TWIST ANGLE IN DEG | 45.0 |
| AHSF | FLANGE QUANTITY | 2 |
| AHSX | FLANGE INSIDE WIDTH | ALL FLANGES INCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126 |
| SFTT | SURFACE TREATMENT | ALL FLANGE INSIDE SURFACES NICKEL |
| CQHN | WAVEGUIDE OUTSIDE WIDTH | INCHES MINIMUM 1.246 AND INCHES MAXIMUM 1.254 |
| AHTD | FLANGE DEPTH | ALL FLANGES INCHES MINIMUM 0.480 AND INCHES MAXIMUM 0.570 |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | ALL FLANGES SINGLE CONNECTION FACILITY INCHES MINIMUM 0.167 AND INCHES MAXIMUM 0.171 |
| CSFC | WAVEGUIDE OUTSIDE HEIGHT | INCHES MINIMUM 0.621 AND INCHES MAXIMUM 0.629 |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | ALL FLANGES SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 8 |
| SFTT | SURFACE TREATMENT | SINGLE TUBING SEGMENT INSIDE SURFACES NICKEL |
| AHSZ | FLANGE OUTSIDE WIDTH | ALL FLANGES INCHES MINIMUM 2.480 AND INCHES MAXIMUM 2.520 |
| AHTA | FLANGE OUTSIDE HEIGHT | FIRST FLANGE INCHES MINIMUM 1.730 |
| CRLB | WAVEGUIDE INSIDE HEIGHT | INCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501 |
| CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | FEET NOMINAL 2.760 |
| CXBD | WAVEGUIDE HEIGHT | INCHES NOMINAL 6.813 |
| AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 |
| AHTX | INSERTION LOSS IN DECIBELS | 0.16 |
| STYL | STYLE DESIGNATOR | |
| AHTA | FLANGE OUTSIDE HEIGHT | SECOND FLANGE INCHES MAXIMUM 1.770 |
| SFTT | SURFACE TREATMENT | SINGLE TUBING SEGMENT OUTSIDE SURFACES OXIDE FILM AND ENAMEL |
| FLEX | FLEXIBILITY | SINGLE TUBING SEGMENT RIGID |
| CTCJ | FLANGE STYLE | |
| AHSY | FLANGE INSIDE HEIGHT | ALL FLANGES INCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501 |
| CRFH | WAVEGUIDE INSIDE WIDTH | INCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126 |