NSN 5930-01-047-7018 · NIIN 010477018 · FSC 5930
NO DASHES 5930010477018
In Stock
SWITCH,PRESSURE
Switches
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WEATHERPROOF |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 5.203 AND INCHES MAXIMUM 5.328 |
| ADAQ | BODY LENGTH | INCHES MINIMUM 4.344 AND INCHES MAXIMUM 4.438 |
| ADAV | OVERALL DIAMETER | INCHES NOMINAL 7.500 |
| AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
| ALAQ | MOUNTING FACILITY CIRCLE RADIUS | INCHES NOMINAL 3.500 |
| AXGY | MOUNTING METHOD | FLANGE AND THREADED STUD(S) |
| CBBL | FEATURES PROVIDED | CALIBRATED SCALE |
| CMLP | THREAD QUANTITY PER INCH | 20 |
| CQJB | PROOF PRESSURE | POUNDS PER SQUARE INCH 500.00 |
| CQJX | NOMINAL THREAD SIZE | SINGLE PRESSURE CONNECTION INCHES 0.250 |
| CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION CIRCULAR |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED 2 |
| CSCF | TERMINAL TYPE | SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | FOURTH VOLTAGE AMPERES RESISTIVE LOAD 4.0 AND AMPERES INDUCTIVE LOAD 2.5 |
| CTHF | CONTACT LOAD CURRENT RATING | THIRD VOLTAGE MILLIAMPERES RESISTIVE LOAD 200.0 AND MILLIAMPERES INDUCTIVE LOAD 100.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 2.5 |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | ACTUATION POINT INCHES OF WATER 0.00 TO 50.00 |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW WITH SCALE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | THIRD VOLTAGE DC AT SEA LEVEL 125.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FOURTH VOLTAGE DC AT SEA LEVEL 30.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 240.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE AC AT SEA LEVEL 125.0 |
| FEAT | SPECIAL FEATURES | SQUARE ROOT SCALE,0-25 GPM,GRADUATIONS AT 5 GPM INTERVALS,6 IN. DIA DIAL |
| THSD | THREAD SERIES DESIGNATOR | SINGLE PRESSURE CONNECTION UNIFIED NATIONAL COARSE (UNC) |